FO Patch Cords

FO Patch Cords

Acc. to ISO/IEC 11801 the fiber channels of duplex connectors are connected, i.e. channel termination A on the 1st side is connected to channel termination B on 2nd side.The channels A/B are marked by differently coloured cable boots (A=red, B=black).


Mechanical Characteristics
Calbe structure acc. DIN/VDE 0888 I-K(ZN)H 2x1 …
Cable dimensions in mm: Zipcord 2,8 x 5,7
Cable dimensions in mm: Minizip 1,8 x 3,7
Max. pulling tension short-term/long-term in N: Zipcord 400 / 200
Max. pulling tension short-term/long-term in N: Minizip 240 / 140
Max. crush resisteance long-torm in N/m: Zipcord 5000
Max. crush resisteance long-torm in N/m: Minizip 2000
Min. bending radius in mm 15
Colour of outer jacket yellow
Weight in kg/km: Zipcord 14,5
Weight in kg/km: Minizip 7,4
Climatic Characteristics
Operating temperature in °C -5 / +55
Storage temperature in °C -30 / +70
Installation temperature in °C -5 / +50
Flame retardancy IEC 60332-1
Halogen-free acc. to IEC 60754-2
Back to Top